Validity of the Liverpool Adverse Events Profile as a Screening Tool for Detecting Comorbid Depression or Anxiety Disorder in People with Epilepsy
Article information
Abstract
Background and Purpose
The Liverpool adverse events profile (LAEP) is useful for detecting and monitoring the adverse effects of antiepileptic drugs (AEDs) and contains items related to symptoms of depression or anxiety. This study evaluated the usefulness of the LAEP for detecting comorbid depression or anxiety disorder in people with epilepsy (PWE).
Methods
PWE, aged from 18 to 70 years and who took AEDs for at least 1 year, were included. They completed the Korean version of the LAEP (K-LAEP) to detect the adverse effects of AEDs and the mini international neuropsychiatric interview-plus version 5.0.0 (MINI) to identify major depressive disorder (MDD) and generalized anxiety disorder (GAD). We validated the K-LAEP as a screening tool for coexisting MDD or GAD in PWE. Receiver operating character (ROC) curve analyses were used to measure the appropriateness of cutoff scores for the total and item K-LAEP scores for detecting MDD or GAD.
Results
The study enrolled 150 PWE. According to the MINI, 30 PWE (20.0%) had MDD and 26 (17.3%) had GAD. Cronbach’s α coefficient of the K-LAEP was 0.939. For the total K-LAEP score, cutoff scores of 40 and 43 could detect MDD and GAD, respectively. For the K-LAEP item score, a cutoff of five could detect MDD or GAD.
Conclusions
The K-LAEP is a valid screening tool for detecting MDD and GAD in PWE. A high LAEP score suggests comorbid psychiatric disorders, which need further specific evaluation.
Introduction
The goal of the management of people with epilepsy (PWE) is to control seizures and improve their quality of life (QOL). However, adverse effects of antiepileptic drugs (AEDs) can significantly impair QOL.1 Hence, it is very important to identify and reduce the adverse effects of AEDs in epilepsy treatment.2 The Liverpool adverse events profile (LAEP) is a 19-item self-report questionnaire that is used to screen adverse effects of AEDs.3 The validity and reliability of various versions of the LAEP have been verified, including English, Spanish, and Korean language versions.2,4,5
The LAEP is useful for detecting and monitoring the adverse effects of AEDs and there is considerable evidence that the total LAEP score is high in depressed or anxious PWE.4–9 This might be because the LAEP contains items pertaining to emotional and psychosomatic symptoms related to depression or anxiety. Conversely, the LAEP may be useful for screening major depression and anxiety.
Psychiatric comorbidities of PWE have negative impacts on outcomes and QOL. To simultaneously identify the psychiatric comorbidities and adverse effects of AEDs, clinicians can administer simple questionnaires, such as the neurological disorders depression inventory for epilepsy (NDDI-E)10 and the generalized anxiety disorder-7 (GAD-7),11 together with the LAEP. However, administering all three inventories at the same time may unnecessarily burden busy epilepsy clinics, although they are rapid screening tools. If the diagnostic value of the LAEP for major depressive disorder (MDD) or generalized anxiety disorder (GAD) is similar to that of the NDDI-E or GAD-7, then we can use the LAEP exclusively for screening MDD or GAD, as well as the adverse effects of AEDs. For this reason, this study evaluated the usefulness of the LAEP for screening MDD and GAD.
Methods
Subjects
Consecutive PWE who had been treated with AEDs for at least 1 year at the epilepsy clinic at Kyungpook National University Hospital since October 2016 were invited to join the study. Patients who were 18 to 70 years old and had a current diagnosis of epilepsy were included. Diagnosis of epilepsy and classification of epilepsy syndrome were performed according to the criteria of the international league against epilepsy (ILAE).12
Patients with an intellectual disability or serious medical, neurological, or psychiatric disorder, or other disorders that prevented them from understanding the questionnaire and cooperating with the interviewer, were excluded. PWE who did not have serious disorders and could cooperate with the interview were not excluded even when taking antidepressants. People with post-stroke epilepsy or history of stroke were not excluded if the stroke status was not serious and they could cooperate the interview.
Study design
The Institutional Review Board (IRB) of Kyungpook National University Hospital approved this cross-sectional study. The IRB number was KNUH 2015-03018. Informed consent was obtained from all participants at the time of enrollment. Demographic and clinical information were collected at an interview in the clinic, and all data were entered into a computer file.
Epilepsy syndrome is of four types: temporal lobe epilepsy (TLE), extra-TLE (epilepsy syndromes in which the epileptic attacks originate from the frontal, parietal, or occipital lobes), generalized epilepsy, and unknown syndrome. The AED regimen was classified as monotherapy or polytherapy according to the number of AEDs the patient was using. Patients were classified into three categories based on seizure control status: uncontrolled (UCE), well-controlled (WCE), and poorly controlled (PCE) epilepsy. UCE (i.e., drug-refractory epilepsy) was defined as an average of more than one seizure per month for 18 months and a maximum seizure-free period of less than 3 months. WCE was defined as freedom from seizures during the preceding year, and PCE was defined as an intermediate degree of seizure control that did not meet the criteria for UCE or WCE.13 The seizure control category of each epilepsy patient was determined based on the seizure frequency documented in their medical records.
Eligible patients completed the Korean version of the LAEP (K-LAEP)5 and the mini international neuropsychiatric interview-plus version 5.0.0 (MINI).14 To measure the validity of the K-LAEP for diagnosing MDD and GAD, a neuropsychologist examined their current MDD, and GAD using the MINI.
Questionnaire and interview
K-LAEP
The K-LAEP is a 19-item self-report questionnaire used to identify and monitor the frequency and severity of common adverse effects associated with AEDs in Korean PWE.4 This questionnaire asks PWE how often adverse effects of AEDs occurred during the past 4 weeks. Each item is scored on a four-point Likert scale: 1, never a problem; 2, rarely a problem; 3, sometimes a problem; and 4, often or always a problem. The total score ranges from 19 to 76, and higher scores are indicative of a greater burden from the adverse effects. The Cronbach’s α coefficient of the K-LAEP is 0.9. We used the 21-item version, which includes two additional items (thinking unclearly and slurred speech) for the QOL study,1 the total possible K-LAEP score in our study ranged from 21 to 84. The item score was defined as the number of items that were scored three or four points.
MINI
The MINI allows a brief and structured clinical interview, and represents the gold standard test for detecting psychiatric disorders based on the Diagnosis and Statistical Manual of Mental Disorders-IV criteria.15 The Korean version of the MINI has been validated.14 The Cohen’s kappa values for diagnosing MDD and GAD using the Korean version of the MINI were 0.71 and 0.57, respectively. Among the various modules of MINI, we used the current time frame of major depressive episode module for MDD diagnosis and the GAD module for GAD diagnosis.
Statistical analysis
The SPSS software package (version 23.0; SPSS Inc., Chicago, IL, USA) was used for the data analysis. MedCalc (version 8.0; MedCalc Software, Mariakerke, Belgium) was used to perform receiver operating characteristic (ROC) analyses, which can provide measures of sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). ROC analyses of the total and item scores of the K-LAEP, over a range of cutoff scores, were performed to compare the MDD and GAD diagnoses with those obtained with the MINI. Optimal cutoff scores were also computed using criteria that minimize the Euclidean distance from point (sensitivity and specificity) to point in the x-y plane. Cronbach’s α was computed as a measure of internal consistency and was recalculated after items were removed. The significance level of the statistical measures was set at p < 0.05.
Results
Initially, 182 patients visited the clinic, but 32 were excluded because they refused to participate (n = 12), had a shorter duration of AED use (n = 6), had an intellectual disability (n = 6), or were too young (n = 5) or too old (n = 3). After all, 150 patients participated in this study.
Frequencies of MDD and GAD determined by the MINI
Table 1 shows the frequencies of MDD and GAD determined by the MINI. MDD was diagnosed in 30 PWE (20%), and GAD in 26 (17.3%).
Reliability of K-LAEP
Cronbach’s α coefficient of the K-LAEP was 0.939. Corrected item-total correlations of items of the K-LAEP are presented in Table 2. The corrected item-total correlation is the correlation of the designated item of K-LAEP with the sum of the other 20. When the correlation is low for a item, the Cronbach’s value will increase if the item is deleted from the inventory. In this study, Cronbach’s α value did not change even if the 21 items of K-LAEP were excluded one by one. Therefore, we could say that all items of the K-LAEP were correlated and well-coordinated (Table 2).
Total score of K-LAEP for detecting MDD and GAD
ROC curve for detecting MDD
Table 3 shows the results of ROC analysis of the total score of the K-LAEP for detecting MDD with the MINI (Fig. 1A). ROC analysis of the total K-LAEP score yielded an area under the curve (AUC) of 0.800 (95% confidence interval [CI] = 0.727–0.861; standard error [SE] = 0.041; p < 0.001). Using a cutoff score of > 40, the sensitivity and specificity were both 80.0%, with a PPV of 50.0% and NPV of 94.1%.
ROC curve for detecting GAD
Table 4 shows the results of ROC analysis of the total score of the K-LAEP for detecting GAD with the MINI (Fig. 1B). ROC analysis of the total K-LAEP score yielded an AUC of 0.793 (95% CI = 0.719–0.855; SE = 0.047; p < 0.001). With a cutoff score of > 43, the sensitivity was 73.1% and the specificity was 85.5%, with a PPV of 51.4% and NPV of 93.8%.
Item score of K-LAEP for detecting for MDD and GAD
ROC curve for detecting MDD
Table 5 shows the results of ROC analysis of the item score of the K-LAEP for detecting MDD with the MINI in (Fig. 2A). As we mentioned above, the item score was defined as the number of items of K-LAEP that were scored three or four points. ROC analysis of the K-LAEP item score yielded an AUC of 0.804 (95% CI = 0.732–0.864; SE = 0.040; p < 0.001). With a cutoff score of > 5, the sensitivity was 83.3% and the specificity 79.6%, with a PPV of 48.1% and NPV of 94.9%.
ROC curve for detecting GAD
Table 6 shows the results of ROC analysis of the item score of the K-LAEP for detecting GAD with the MINI (Fig. 2B). ROC analysis of the K-LAEP item score yielded an AUC of 0.779 (95% CI = 0.704–0.842; SE = 0.044; p < 0.001). At a cutoff score of > 5, the sensitivity was 80.8% and the specificity 75.0%, with a PPV of 40.4% and NPV of 94.9%.
Discussion
The treatment goal in epilepsy is to improve QOL as well as to control seizures. However, it is impossible to avoid adverse effects entirely when using AEDs. PWE may also complain of negative events that are not directly related to AEDs, but instead occur coincidentally while using AEDs.9 Detection and reduction of these adverse effects is very important in the management of PWE, because they can interfere with the maintenance of effective AEDs and may even reduce QOL.2 Reports have shown that depression and anxiety are associated with a high total LAEP score.4–9 This being so, clinicians should clarify whether a high total LAEP score is likely to be associated with psychiatric disorders such as MDD and GAD, because these illnesses have a serious impact on QOL and the mortality rate of PWE.8,16
The association between a high total LAEP score and depression and anxiety may be a drawback when using the instrument as a screening tool for common adverse effects of AEDs. Depression and anxiety affect the total LAEP score because it contains items that are related to emotional and psychosomatic symptoms, and depression and anxiety may cause those emotional and psychosomatic symptoms independent of AEDs. Anxiety was even shown to be associated with high scores on items pertaining to acne, hair loss, weight gain, and mouth problems, which are not emotional in nature and do not seem to be associated with psychosomatic symptoms.7 On this basis, we hypothesized that the LAEP may be useful for screening for MDD and GAD.
Most outpatient epilepsy clinics are too busy to evaluate all aspects of PWE. If we have a quick inventory that can examine many aspects of PWE, we can efficiently use the inventory in a busy epilepsy clinic. Hypothesizing that the LAEP may be useful for screening for MDD and GAD, we conducted this validation study based on a gold standard test, i.e., the MINI. We found that LAEP was useful for screening for MDD and GAD. Therefore, the LAEP serves not only as a standardized tool for monitoring the common adverse effects of AEDs, but can also be used to screen for MDD and GAD.
Rapid screening of depression and anxiety is more important in UCE than in WCE. Depression and anxiety occur more frequently in PWE whose seizures are not well-controlled.17 Patients with newly diagnosed epilepsy are more likely to develop resistance to AEDs when depression and anxiety are present.18,19 Depression and anxiety in PWE have also been shown to negatively affect the outcomes of pharmacologic and surgical treatments of epilepsy.20,21 For this reason, LAEP would be useful for screening for depression and anxiety in UCE.
We validated that the LAEP is useful for screening MDD and GAD through this study. This study has a fundamental limitation because the LAEP is a inventory developed to monitor common adverse effects of AEDs. In patients without MDD or GAD, multiple side effects from AEDs can be mis-screened for MDD or GAD. Nevertheless, the results of this study suggested that the LAEP could be used as a multimodal screening tool in busy epilepsy clinics.
The LAEP is a standard screening tool for identifying and monitoring common adverse effects of AEDs. It is easy to use the LAEP in a busy epileptic clinic because the LAEP is simple and takes a short time. The LAEP usually takes less than 5 minutes to complete.22 Our results, and the rapidity of the test, underscore the usefulness of the LAEP. If the total LAEP score is high in PWE, we should consider comorbid depression and anxiety as well as the adverse effects of AEDs. Taken together, a high LAEP score signifies that depression and anxiety should be investigated further; such investigations could include gold standard tests, such as the MINI, and psychiatric consultation.
Notes
Conflicts of Interest
The authors have no financial or other potential conflicts of interest to declare in relation to this study.